These values are in reference to mechanically attached insulation cover.
Tectum roof deck weight.
Tectum e tectum e n composite roof deck solution with excellent sound absorption r values up to 43 with eps or gps insulation options.
Weight psf 1 1 2 6 1 2 9 36 11 6 0 1 total thickness includes two layers of 7 16 osb.
For that reason low weight metal roof systems can be a very good option.
Tectum iii tectum iiip composite roof deck solution with good sound absorption r values up to 44 and high humidity application performance.
2 r values include air films and built up roofing.
East lawrence recreation center lawrence ks tectum i roof deck key selection attributes sound absorption nrc up to 0 80 r value up to 6 spans up to 6 feet 50 pound design load standard widths diaphragm shear up to 542 dsn lf nailable surface low slope applications tectum i structural acoustic roof deck provides excellent sound absorption a thermal.
Tectum 1 thick 2 0psf insulrock 1 thick 2 7psf poured gypsum 1 thick 6 5psf vermiculate concrete 1 thick 2 6psf.
Trufast screws 6 o c.
Pfs 1 96 108 120 132 144 comp.
Tectum i structural acoustic roof deck provides excellent sound absorption a thermal barrier for field applied foam plastics and is compatible with a wide variety of insulation and roofing materials.
Proven economical roof decking solution for over 65 years miami dade noa approved 18 0619 03 tectum iiiw tectum structural acoustical roof deck 4 7 10 11 14 19 tectum i roof deck panels tectum composite roof deck panels code compliance product overview design data sustainability acoustics selection criteria.
Plank v 9 6 0 112 88 72 59 50 for loads greater than 200 lbs contact armstrong techline.
The information listed in the chart below is for use with the referenced roof deck fastener type minimum pullout values and required penetration depths based on fasteners type.
End joints must fall over supporting members.
Tectum roof deck interior solutions from armstrong world industries.
1 thickness and weight are nominal.
Steel deck absorption values for greater that 1000 hertz consistently are lower.
Tectum roof deck systems continue to outperform all structural acoustical roof decks including the acoustical steel deck perforated tin.
An nrc up to 1 00 on specific systems.
For re roofing over tectum keep in mind that tectum can soften as it ages.
Additionally if hook nails were used to install the previous roof it will be impossible to remove the old roofing without destroying the tectum decking.
Roof deck wall ceiling panels when noise control durability matter.